Connection
Only RFD-R
Only RFD-R-D
Standards and guidelines
Maintenance
Functional description
Ceiling swirl diffusers allow the supply air from ventilation systems to flow into the room in a swirl pattern. The resulting airflow induces high levels of room air, thereby rapidly reducing the airflow velocity and the temperature difference between supply air and room air. Ceiling swirl diffusers allow for large volume flow rates. The result is a mixed flow ventilation in comfort zones, with good overall room ventilation, creating only very little turbulence in the occupied zone.
Type RFD ceiling swirl diffusers have fixed blades. Air discharge is horizontal with an omni-directional flow. The supply air to room air temperature difference may range from –12 to +10 K.
A damper blade (optional) simplifies volume flow rate balancing for commissioning. Pressure tap and cord-operated damper blade (optional) allow for volume flow rate balancing with the diffuser face in place.
To give rooms an aesthetic, uniform look, Type RFD diffusers may also be used for extract air.
Nominal sizes | 125, 160, 200, 250, 315, 400 mm |
Minimum volume flow rate, with ΔtZ = –6 K | 4 – 36 l/s or 14 – 130 m³/h |
Maximum volume flow rate, with LWA ≅ 50 dB(A) | 22 – 330 l/s or 79 – 1188 m³/h |
Supply air to room air temperature difference | –12 to +10 K |
This specification text describes the general properties of the product. Texts for variants can be generated with our Easy Product Finder design program.
Ceiling swirl diffusers with square or circular diffuser face. Supply air and extract air variants for comfort zones and industrial zones. Diffuser face with fixed air control blades for horizontal swirling supply air discharge creating high induction levels. Ready-to-install component which consists of the diffuser face with radially arranged fixed air control blades and either a spigot only or a plenum box with side entry or top entry spigot, and suspension holes or suspension lugs. The diffuser face is fixed to the cross bar with a central screw. Spigots are suitable for ducting according to EN 1506 or EN 13180. Sound power level of the air regenerated noise measured according to EN ISO 5135.
Special characteristicsLife cycle assessment
A life cycle assessment is available for the product series in form of an Environmental Product Declaration (EPD) that has been checked and published by a programme holder.
Podeli stranicu
Preporuči ovu stranicu
Preporuči ovu stranicu slanjem linka putem email poruke.
Podeli stranicu
Zahvaljujemo se na Vašoj preporuci!
Vaša preporuka je poslata i biće uskoro isporučena.
Kontakt
Tu smo za vas
Molimo Vas da navedete sadržinu poruke i vrstu zahteva
Tel.: +381 11 2622 543 | Fax: +49 (0)2845/202-265
Kontakt
Zahvaljujemo na vašoj poruci!
Vaša poruka je poslata i biće uskoro obrađena.
Naše odeljenje za servisnu podršku će Vas kontaktirati u najkraćem roku.
Za opšta pitanja u vezi proizvoda ili usluga možete takoše da pozovete:
Tel.: +381 11 2622 543 | Fax: +381 11 2624 150
Kontakt
Tu smo za vas
Molimo Vas da navedete sadržinu poruke i vrstu zahteva
Tel.: +381 11 2622 543 | Fax: +49 (0)2845/202-265
Kontakt
Zahvaljujemo na vašoj poruci!
Vaša poruka je poslata i biće uskoro obrađena.
Naše odeljenje za servisnu podršku će Vas kontaktirati u najkraćem roku.
Za opšta pitanja u vezi proizvoda ili usluga možete takoše da pozovete:
Tel.: +381 11 2622 543 | Fax: +381 11 2624 150